What's new in Zond 265 4.5.1904.1
Apr 10, 2019
- Features:
- Updated AV1 decoder (Windows version, compatible with reference software AOM 1.0.0, commit date 2018-12-25, 9b1252eab0616d2c1f6d7990c6256441c0b6483f)
- Added support of MP4 and MPEG Dash files with AV1 video (Windows version)
- Fixes:
- Decoding artifacts on some files with AVC video
- Crashes on files with multiple slices AVC video
- Opening files with non-ansi characters in path
- Crashes on positioning during VMAF values calculation
- Incorrect VMAF values on files with interlaced HEVC video
- Decoded picture overlays scaling on high DPI displays
New in Zond 265 3.1.1603.16 (Mar 17, 2016)
- Fixes:
- MP4 file cannot be opened if some of its frames have size more than 2 MB
- Problems with license activation if license file was assigned to disabled network adapter
New in Zond 265 3.1.1603.3 (Mar 4, 2016)
- Features:
- Support of MP4 (MPEG-4 Part 12) file format for HEVC/H.265 and AVC/H.264 video streams
- Fixes:
- Wrong preview picture on frames with dimensions not multiple of 4
New in Zond 265 3.1.1602.12 (Feb 17, 2016)
- Features:
- Increased speed with translucent overlays of the image of encoded file (PU, TU, QP, Bits, RefIdx, PSNR) for high-resolution files: the mapping, scaling, response to mouse movement
- Added data in the generated report in the console mode: average PSNR and SSIM for the whole file, file size, duration, bitrate
- Fixes:
- PDF specification file was not displayed
- Extra blank lines in the report file was removed
- Fixed the crash on files with the data of HRD model if there are some pic_timing SEI missed
- Fixed a problem with opening a HEVC file if it does not begin with a key frame with a large value of the Picture Order Count
- Displaying of an error message when opening an unsupported file
- The current marker was not updated sometimes
New in Zond 265 3.1.1509.22 (Dec 29, 2015)
- Features:
- Frame Stats tab displays Luma/Chroma Intra Prediction Mode Statistics
- Intra Prediction Mode Statistics report from CLI
- Zond 265 now launches in NW.js runtime instead of web-browser
New in Zond 265 3.1.1508.28 (Oct 20, 2015)
- Features:
- Frame Stats tab displays Luma/Chroma Intra Prediction Mode Statistics
- Intra Prediction Mode Statistics report from CLI
- Zond 265 now launches in NW.js runtime instead of web-browser
New in Zond 265 3.0.1506.17 (Oct 20, 2015)
- Features:
- HEVC stream validation conformance according to the specification in GUI and CLI available
- Compatible with the reference software HM 16.5
- New HRD building mode. CPB fullness analysis based on SEI messages of the stream
- GOP length statistics
- Expansion of NAL unit headers in Bitstream tab
- Specific highlight of key frames on Frame Bars tab
- Simplified management of personal and floating licenses activation
- Added GUI managing to license server ( before only CLI was available )
- Added information to clients which IPs uses ZOND currently (for floating license)
- No need any more write access to "Program Files" for activation
New in Zond 265 2.0.1412.26 (Oct 20, 2015)
- Features:
- HEVC stream errors detection. Available in an “Error” tab and as CLI report
- Mac OS X version of ZOND for HEVC streams
- Support of MPEG-2 Transport Stream for HEVC/H.265 and AVC/H.264 streams
- H.264/AVC support in a release mode
- Compatible with the reference software HM 16.2
- Support of 4:4:4, 4:2:2, 4:0:0 chroma format for HEVC
- Support of 10 bits video compression for HEVC
- Delivering Short Term Reference Picture Set in Frame info Tab
- Optimized CLI reports generation process for more than one simultaneous reports per run
New in Zond 265 1.9.1410.9 (Oct 20, 2015)
- Features:
- Compatible with the reference software HM 14
- 4K big optimization. 5 times faster handling UltraHD 4K files. Testing PC Intel Core i7-2600 3.4GHz, 16GB RAM, Windows 7 x64 comparing with 1.8.1407.29
- H.264/AVC video elementary streams supported in a beta mode
- CLI reports can have now CU data for entire frame, frame and stream statistics
- Saving as a YUV files different stages of picture decoding in command line mode: final, after deblock, before deblock, residual, predicted
- Resizable layout. Now it can be shrinked with no minimal size of a width
- Fixes:
- If a stream had cropping requirements, wrong quality metrics would be calculated
- Quality metrics were not calculated if YUV file had 1 frame
- It could crash if two different HEVC files were loaded in two ZOND instances / browser tabs
- Some streams errors handling added
- Fixed table sorting in a Frame Stats tab
- Wrong scrolling when expanding bitstream header
- Info about pixel number predicted from a definite reference picture is missed
- Sometimes navigating through HEX hanged Zond
- Sometimes headers values contained garbage
New in Zond 265 1.8.1407.29 (Oct 20, 2015)
- Features:
- Quality estimation comparing original YUV file with preloaded HEVC file by PSNR and MSSIM metrics
- Quality graph to show separate PSNR /MSSIM values for separate Y, U,V channels Visual map of PSNR for a frame coded tree blocks (CTB)
- HEVC specification quotes for most of syntax elements. Just put a mouse pointer to any element name and get an information scope or open a specification at the necessary place (the specification should be downloaded and placed to a necessary folder)
- Command line interface for quality estimation
- Showing a residual picture type
- Playback ability enabled
- Copying a bitstream slice in detail to a clipboard
- Compatible with HM13 and previous HMs starting from HM 10.01
- Floating license server shows names of PCs / IP addresses of a current users
- Fixes:
- Optimized HEVC files opening and processing. It works 50-60 % faster than previous version
- Improved Zond operating stability. Fixed many crashes and hangs
- Improved last frame navigation in case it is not complete
- Fixed. TU partition was sometimes shown overlapped
- Fixed. Wrong handling of frames with negative POC after IDR
New in Zond 265 1.5.1312.05 (Oct 20, 2015)
- Features:
- Hex viewer displays file contents in binary and hexadecimal formats with the abilities to search and navigate.
- Hex pannel is fully movable, resizable and hidable.
- Hex viewer is synchronized with a bitstream tab and highlights header blocks and bitstream header bits. It has been significantly optimized compared to betas and demos.
- Added the support for reading HEVC streams from MPEG transport streams in a beta vesion.
- Compatible with the reference software HM 12.1.
- Fixes:
- Opening file procedure was optimized. Now it works faster for large files.
- Optimized action responses for large files: mouse clicks, data showing.
- 1 frames stream could not be opened.
- Open file dialog has now OnTop property as it happened that is didn't arise.
- Calling a nonexistent file from a history didn't deliver an error.
- Hanging on some large files.
- Crashes on some files.
- Display order was shown incorrectly if slice_pic_order_cnt_lsb had some skips.
- Changes:
- Stream statistics parsing moved to a separate procedure. It is managed in Stream Stats tab. Can be paused and resumed.
New in Zond 265 1.4.1306.20 (Oct 20, 2015)
- Features:
- Compatible with reference software HM 11
New in Zond 265 1.4.1302.18 (Oct 20, 2015)
- Features:
- Compatible with reference software HM 10
- Shows video parameter set (VPS) structure
- Shows supplemental enhancement information (SEI)
- Extended stream statistics - CU types, Reference pictures, Intra/Inter PU sizes, TU (Y / Cb / Cr) sizes
- Sorting frame / stream statistics elements (residuals, mvd, etc.) by default order or by percentage
- Shows a progress while file loading / parsing
- Changes:
- A zoom mode changed. A filter was applied that altered visual pixels in a picture zoomed in. Cancelled
- Zond is now automatically launched in Google Chrome (if installed) despite of what browser is default one.
- New values in fields of HRD Buffer (bitrate, framerate. etc. ) are updated by Enter keyboard button (as well as by “Rebuild”)
- “Recent Files” drop-down list is not any more closed if a mouse pointer goes up
- Fixes:
- Sometimes if to close Zond browser tab, the process was not killed and remained running
- Sometimes Intra 64x64 blocks were depicted with incorrect additional subpartition at PU / CU overlay grid
New in Zond 265 1.3.1212.4 (Oct 20, 2015)
- Features:
- Compatible with reference software HM 9.1
- Picture tiles partitioning bounds. Layout menu-> "Tile Boundaries" button
- Tile index information in CU tab
- Stream statistics. Bitrate, average frame size, I/P/B frame size
- Performance optimisation while stream loading
- Extended frame statistics (frame stats tab). Compression efficiency: number of bits, bits per bin, bits per pixel, compression ratio, motion vectors per pixel